User Interface
Manual Control
Select the Manual Control option from the top level menu options, and press the ENT key to enter the Manual Control menu. The following options are available:
Use the cursor keys to scroll between the options. Press the ENT key to enter the menu for the selected option.
Channel: xx
Level: xxx
The cursor is shown in the Channel field. The channel number defaults to 1.
ChilliNet mode
When operating in ChilliNet mode, the screen shows:
A (xx) Channel: xx
Level: xxx
The cursor is shown in the Channel field. The channel number defaults to 1.
The area number A(xx) shows the area that the dimmer channel is assigned to and is for information only.
Level Adjustment
In both Standard and ChilliNet modes, individual channel levels can then be adjusted using the numeric keypad or cursor keys. When the cursor is in the Channel field, enter the channel number using the numeric keys then press the ENT key. The manual control level for the channel is shown in the Level field and the cursor moves to the Level field. When cursor is in the Level field, enter the required level (0 – 100) using the numeric keys then press the ENT key. The output of the dimmer channel matches the level entered, the cursor returns to the Channel field.
The A> key can be used to increase the field value by 1, and the B< key can be used to decrease the field value by 1.
The # key can be used as a quick method of setting the manual control levels to full or off. The first push will take it 100%, the second push will take it 0% etc.
All Channels
Level: 0
ChilliNet Mode
In ChilliNet mode you can set a manual control level for all the channels in a specified area on the dimmer in a single operation.
Select the Set All Chans option from the menu, and press the ENT key. The screen shows:
Area: 1
Level: 0
The cursor is in the Area field. Press the ENT key to move between the Area and Level fields. The area number must be valid (i.e. the dimmer has one or more channels assigned to that area) to adjust the Level field.
Level Adjustment
In both Standard and ChilliNet modes, when the cursor is in the Level field you can enter the required level (0 – 100) using the numeric keys then press the ENT key. The output of the dimmer channels matches the level entered.
The A> key can be used to increase the field value by 1, and the B< key can be used to decrease the field value by 1.
The # key can be used as a quick method of setting the manual control levels to full or off. The first push will take it 100%, the second push will take it 0% etc.