Sequences
Program Sequence
Select
Sequence: 1
Use the numeric or cursor keys to select the required sequence number, then press the ENT key. The screen shows:
Seq 1 Step: 1
Memory: xx
The cursor appears in the Step field.
The Memory field shows the contents of the step, if programmed, or “xx” if the step is not programmed.
Select the first step in the sequence, then press the ENT key. The cursor moves to the Memory field.
Use the cursor keys to select one of the programmed memories in the dimmer. Press the ENT key to assign the memory to the selected step. The cursor returns to the Step field.
Use the cursor keys to select the next step in the sequence, then press the ENT key. The cursor moves to the Memory field.
Use the cursor keys to select one of the programmed memories in the dimmer. Press the ENT key to assign the memory to the selected step. The cursor returns to the Step field.
Repeat the above process until all the steps in the sequence have been programmed (maximum of 12 steps).
Press the ESC key to return to the Select Sequence screen.
Sequence: 1
Area: 1
The cursor appears in the Sequence field. Use the numeric or cursor keys to select the required sequence number.
Press the ENT key. The cursor moves to the Area field. Use the numeric or cursor keys to select the required area. Press the ENT key. The screen shows:
Seq 1 Step: 1
Memory: xx
The cursor appears in the Step field. The Memory field shows the contents of the step, if programmed, or “xx” if not programmed.
Select the first step in the sequence, then press the ENT key. The cursor moves to the Memory field.
Use the cursor keys to select the required memory number (1 - 12). Press the ENT key to assign the memory to the selected step. The cursor returns to the Step field.
Use the cursor keys to select the next step in the sequence, then press the ENT key. The cursor moves to the Memory field.
Use the cursor keys to select the required memory number (1 - 12). Press the ENT key to assign the memory to the selected step. The cursor returns to the Step field.
Repeat the above process until all the steps in the sequence have been programmed (maximum of 12 steps).